EMP防护用滤波器

厂  牌 : ETS-Lindgren

ETS-Lindgren EMP/HEMP power line filters offer excellent multi-stage over-voltage and EMI/RFI protection. These single unit filters are available in either two or four individually filtered lines, with ratings of 227/480 VAC, 10 A - 1250 A.

  • High Frequency Response Design
  • Reliable Transient Suppression Elements
  • Superior Insertion Loss Performance
  • Extended Filter Life
  • Pulse Current
  • Wide Selection of Current Ratings
  • Custom Designs Available

Ideal Protection for Demanding Environments

ETS-Lindgren EMP/HEMP power line filters offer excellent multi-stage over-voltage and EMI/RFI protection. These single unit filters are available in either two or four individually filtered lines, with ratings of 227/480 VAC, 10 A - 1250 A.
These EMP/HEMP series filters are available in the following configurations:

  • Individual, Stand-alone Single Circuit Filters
  • “Twin” Dual Circuit Filters for Single Phase Installations
  • Multiple Line Panel Filters for Facility Installations
    -- Single Phase
    -- Three Phase

All EMP/HEMP filters meet or exceed the following performance and safety criteria:

Individual EMP/HEMP Power Line Filters: LRX-EMP Series

The LRX-EMP series of filters is available for individual mounting requirements. These filters are supplied in two case styles. The Style 2 (designated as S2) case configuration is designed for direct installation on a shielded room. The Style 3 (designated as S3) case configuration is designed for installation within a shielded filter panel. Style 3 filters can be supplied as individual replacement filters for installation within the LPRX-EMP and LFPRX-EMP filter panels.

Model NumberCurrent RatingCase Dimension: Height "A"Case Dimension: Width "B"Case Dimension: Depth "C"Approx. Weight 
LRX-1030-EMP-*30 A64.8 cm (25.5 in.)11.4 cm (4.5 in.)11.4 cm (4.5 in.)10.4 kg (23 lbs.)
LRX-1060-EMP-*60 A85.1 cm (33.5 in.)15.2 cm (6 in.)17.8 cm (7 in.)18.1 kg (40 lbs.)
LRX-1100-EMP-*100 A85.1 cm (33.5 in.)15.2 cm (6 in.)17.8 cm (7 in.)20.4 kg (45 lbs.)
LRX-1250-EMP-*250 A95.3 cm (37.5 in.)20.3 cm (8 in.)25.4 cm (10 in.)45.4 kg (100 lbs.)
LRX-1400-EMP-*400 A103.6 cm (40.8 in.)20.3 cm (8 in.)30.5 cm (12 in.)54.4 kg (120 lbs.

*Please specify either S2 (Style 2) or S3 (Style 3) configuration.

“Twin” Dual Circuit EMP/HEMP Power Line Filters: LRX-EMP Series

“Twin” dual circuit power line filters are designed for wall-mounted installation, and use on AC or DC power lines. These filters can be used for either two-wire AC systems with both lines above ground or three-wire AC systems where one of the conductors is at ground potential and grounded to the filter case.

Model NumberCurrent RatingCase Dimension: Height "A"Case Dimension: Width "B"Case Dimension: Depth "C"Approx. Weight 
LRX-2010-EMP2 x 30 A94.0 cm (37 in.)22.89 cm (9 in.)12.7 cm (5 in.)31.8 kg (70 lbs.)
LRX-2030-EMP2 x 30 A94.0 cm (37 in.)22.89 cm (9 in.)12.7 cm (5 in.)31.8 kg (70 lbs.)
LRX-2060-EMP2 x 60 A111.8 cm (44 in.)35.6 cm (14 in.)15.2 cm (6 in.)36.3 kg (80 lbs.)
LRX-2100-EMP2 x 100 A111.8 cm (44 in.)35.6 cm (14 in.)15.2 cm (6 in.)45.4 kg (100 lbs.)
LRX-2250-EMP2 x 250 A121.9 cm (48 in.)35.6 cm (14 in.)15.2 cm (6 in.)54.4 kg (120 lbs.)
LRX-2400-EMP2 x 400 A132.1 cm (52 in.)61.0 cm (24 in.)22.9 cm (9 in.)90.7 kg (200 lbs.)

Multiple Line EMP/HEMP Filters in Panels: LPRX-EMP & LFPRX-EMP Series

The LPRX-EMP AND LFPRX-EMP series filters are available in NEMA 1 type panels for wall-mounted and floor-standing installations. These panels incorporate an EM/RFI tight compartment (security well) that meets the highest performance criteria: a full 100 dB shielding effectiveness from 14 kHz to 40 GHz.
 Model NumberCurrent RatingCase Dimension: Height "A"Case Dimension: Width "B"Case Dimension: Depth "C"Approx. Weight
LPRX-2x30-EMP2 x 30 A91.4 cm (36 in.)30.5 cm (12 in.)15.2 cm (6 in.)36.3 kg (80 lbs.)
LPRX-3x30-EMP3 x 30 A91.4 cm (36 in.)45.7 cm ( 18 in.)15.2 cm (6 in.)49.9 kg (110 lbs.)
LPRX-4x30-EMP4 x 30 A91.4 cm (36 in.)61.0 cm (24 in.)15.2 cm (6 in.)63.5 kg (140 lbs.)
LPRX-2x60-EMP2 x 60 A121.9 cm (48 in.)40.6 cm (16 in.)21.6 cm (8.5 in.)63.5 kg (140 lbs.)
LPRX-3x60-EMP3 x 60 A121.9 cm (48 in.)35.6 cm (14 in.)21.6 cm (8.5 in.)90.7 kg (200 lbs.)
LPRX-4x60-EMP4 x 60 A121.9 cm (48 in.)76.2 cm (30 in.)21.6 cm (8.5 in.)117.9 kg (260 lbs.)
LPRX-2x100-EMP2 x 100 A121.9 cm (48 in.)40.6 cm (16 in.)21.6 cm (8.5 in.)68.0 kg (150 lbs.)
LPRX-3x100-EMP3 x 100 A121.9 cm (48 in.)61.0 cm (24 in.)21.6 cm (8.5 in.)97.5 kg (215 lbs.)
LPRX-4x100-EMP4 x 100 A121.9 cm (48 in.)76.2 cm (30 in.)21.6 cm (8.5 in.)81.6 kg (180 lbs.)

NOTE: For 250 A to 1250 A Wall Mounted filters, please contact your ETS-Lindgren representative.

 Model NumberCurrent RatingCase Dimension: Height "A"Case Dimension: Width "B"Case Dimension: Depth "C"Approx. Weight
LFPRX-2x250-EMP2 x 250 A188.0 cm (74 in.)50.8 cm (20 in.)35.6 cm (14 in.)163.3 kg (360 lbs.)
LFPRX-3x250-EMP3 x 250 A188.0 cm (74 in.)76.2 cm (30 in.)35.6 cm (14 in.)231.3 kg (510 lbs.)
LFPRX-4x250-EMP4 x 250 A188.0 cm (74 in.)99.1 cm (39 in.)35.6 cm (14 in.)299.4 kg (660 lbs.)
LFPRX-2x400-EMP2 x 400 A188.0 cm (74 in.)50.8 cm (20 in.)35.6 cm (14 in.)172.4 kg (380 lbs.)
LFPRX-3x400-EMP3 x 400 A188.0 cm (74 in.)76.2 cm (30 in.)35.6 cm (14 in.)244.9 kg (540 lbs.)
LFPRX-4x400-EMP4 x 400 A188.0 cm (74 in.)99.1 cm (39 in.)35.6 cm (14 in.)317.5 kg (700 lbs.)
LFPRX-3x600-EMP3 x 600 A208.3 cm (82 in.)119.4 cm (47 in.)45.7 cm (18 in.)453.6 kg (1000 lbs.)
LFPRX-4x600-EMP4 x 600 A208.3 cm (82 in.)119.4 cm (47 in.)45.7 cm (18 in.)453.6 kg (1000 lbs.)
LFPRX-3x800-EMP3 x 800 A196.9 cm (77.5 in.)111.8 cm (44 in.)71.1 cm (28 in.)589.7 kg (1300 lbs.)
LFPRX-4x800-EMP4 x 800 A196.9 cm (77.5 in.)111.8 cm (44 in.)71.1 cm (28 in.)589.7 kg (1300 lbs.)
LFPRX-3x1200-EMP3 x 1200 A232.4 cm (91.5 in.)124.5 cm (49 in.)86.4 cm (34 in.)816.5 kg (1800 lbs.)
LFPRX-4x1200-EMP4 x 1200 A232.4 cm (91.5 in.)124.5 cm (49 in.)86.4 cm (34 in.)816.5 kg (1800 lbs.)
LFPRX-3x1250-EMP3 x 1250 A232.4 cm (91.5 in.)124.5 cm (49 in.)86.4 cm (34 in.)816.5 kg (1800 lbs.)
LFPRX-4x1250-EMP4 x 1250 A232.4 cm (91.5 in.)124.5 cm (49 in.)86.4 cm (34 in.)816.5 kg (1800 lbs.)
LFPRX-EMP Filter (Floor Mounted, 100 dB, 14 kHz - 40 GHz)
Designed to Meet Point-of-Entry Requirements of MIL-STD-188-125-1 & -2 for Short and Intermediate Pulses in Addition to High Insertion Loss Performance for SCIF, TEMPEST and Other Military and Commercial Applications

High Frequency Response Design

Our filters use a high frequency feed-through capacitor design, which provides better high frequency response.

Reliable Transient Suppression Elements

Our filters use suppression elements. These elements protect both the filter and the connected equipment by absorbing and diverting power to ground.

Superior Insertion Loss Performance Our filters perform at 100 dB from 14 kHz - 40 GHz at full load. This provides better EMI, RFI, HIRF and IEMI attenuation performance.

Extended Filter Life

Our filters use oversized inductors for low loss and low temperature rise, resulting in extended filter life. Filter life is further extended by incorporating self-healing capacitors.

Pulse Current

Our filters are fitted with high transient suppressors in front of the inductive input circuit. This feature results in very low residual currents during an EMP pulse, protecting the connected equipment.

Wide Selection of Current Ratings

These filters are available in configurations of 10 A, 30 A, 60 A, 100 A, 250 A, 400 A, 600 A, 800 A, 1200 A, and 1250 A at 277/480 VAC.

Custom Designs Available

Need something special? ETS-Lindgren can custom design a filter specific to your exact needs. Please contact the ETS-Lindgren Sales Department for further details.

Pulse Suppression Performance

MIL-STD-188-125-1 acceptance test, intermediate pulse current injection, wave-shape 1.5/3000μs

Input Pulse AmplitudeMIL-STD-188-125 RequirementTypical Filter Response
250 ANo Filter Damage or Performance DegradationNo Filter Damage or Performance Degradation

Pulse Suppression Performance

MIL-STD-188-125-1 acceptance test, short pulse current injection, wave-sharp e 20/500 ns

Input Pulse AmplitudeMIL-STD-188-125 Residual Requirement And Filter Residual Let Through
250 A< 10 A
500 A< 10 A
1000 A< 10 A
1800 A< 10 A
2500 A< 10 A

Insertion Loss Performance*

Minimum Loss in 50 ? system with/without load
FrequencyInsertion Loss
14 kHz100 dB
1 MHz100 dB
10 MHz100 dB
100 MHz100 dB
1 GHz100 dB
10 GHz100 dB
40 GHz100 dB

*Both Symmetric and Asymetric

Ratings and Characteristics

Rated VoltageTest VoltageInsulation ResistanceDischarge ResistorsDischarge TimeMax. Temp. Rise on Full LoadFull Load Oeprating Temp. RangeLeakage Current at 250 VAC 50 HzPeak Surge Current
0 - 277/480 VAC
50/60 Hz
2250 VDC Each Line to Case per UL 1283 and LVD (Prior to Fitting Transient Suppressors> 100 M? (Prior to Fitting Discharge Resistors)Fitted Internally from Each Line to Case<30 sec.25°
C
-25°C to 65°
C
<10% of Rated Current70 kA (8/μs)

Technical Charts

EMP Commercial and Defense Tempest Powerline Filters

永远超越客户的期待
ALWAYS GOES BEYOND CUSTOMERS' EXPECTATIONS

CONTACT US