A semi-anechoic chamber, the SpaceSaver 26H is designed to perform ANSI C63.4/CISPR 16-1-4 and IEC 61000-4-3 compliant radiated immunity measurements.
Ultra Broadband Frequency Range: 26 MHz - 40 GHz
- Radiated Immunity Compliance
- IEC 61000-4-3
- Radiated Emissions Pre-Compliance
- Semi Anechoic (Pre-Scan)
- ANSI C63.4/CISPR 16-1-4
- Fully Anechoic
- CISPR 16-1-4 (Fixed height)
Turnkey Chamber Solutions
Description
SPACESAVER PC
A semi-anechoic chamber, the SpaceSaver PC is designed to perform ANSI C63.4/CISPR 16-1-4 and IEC 61000-4-3 pre-compliant radiated immunity measurements.
This chamber can also be used for ANSI C63.4 pre-compliant radiated emissions measurement prescans, with limited height scan.
Frequency ranges for this chamber are 80 MHz to 40 GHz (radiated immunity) and 30 MHz to 40 GHz (radiated emission).
SPACESAVER 26H
A semi-anechoic chamber, the SpaceSaver 26H is designed to perform ANSI C63.4/CISPR 16-1-4 and IEC 61000-4-3 compliant radiated immunity measurements.
This chamber can also be used for ANSI C63.4 pre-compliant radiated emissions measurement prescans, with limited height scan.
Frequency ranges for this chamber are 26 MHz to 40 GHz (radiated immunity) and 30 MHz to 40 GHz (radiated emission).
SPACESAVER FAR
A fully anechoic chamber, the SpaceSaver FAR is designed to perform IEC 61000-4-3 compliant radiated immunity measurements.
This chamber can also be used for CISPR 16-1-4 pre-compliant radiated emissions measurement prescans, with fixed height.
Frequency ranges for this chamber are 26 MHz to 40 GHz (radiated immunity) and 30 MHz to 40 GHz (radiated emission).
Options
- Sliding doors for flush-threshold opening
- Fire detection and suppression systems
- Immunity Interlock Switch
- Chamber Testing (See Performance Tables)
- Heating, Ventilation, & Air Conditioning (HVAC) Systems
- Electrical distribution
- CCTV monitoring system
- Raised reflective ground plane floor system
- Various sizes of series 201 RF shielded swing doors
- Intercom system
- Structural design calculations and certification
- Additional filtering
- Polystyrene Wall Covering Over Ferrite
- Antennas
- Immunity Only
- 3109 Biconical
- 3148B Log Periodic
- Emissions Only
- 3110C Biconical
- 3148B Log Periodic
- Immunity and Emissions
- 3104C Biconical (50 w max.)
- 3148B Log Periodic
- 3142D Log Periodic
- Towers and Tripods
- Immunity Only
- 4-TR Tripod
7-TR Tripod (SpaceSaver PC) - Immunity and Emissions
2175-2 MiniMastTM
- Positioners
- Low Reflective Table
- 2165-1.21, LoPro 1.2 m diameter
- 2188-1.23, 1.2 m diameter
(requires 160 mm (6”) raised floor) - 2188-1.53, 1.5 m diameter
(requires 160 mm (6”) raised floor)
- Probes
- HI-6005
- HI-6105