- 26 MHz - 40 GHz Performance Range
- Available as a Turnkey Package:
- Chamber, Tower, Turntable, Antennas, Instrumentation and Software - Eligible for FCC 3 Meter Class B Facility Filing
- Full Compliance Testing for Radiated Emissions:
- ANSI C63.4
- FCC Parts 15 & 18
- EN 50147-2
- CISPR 11/EN50011
- CISPR 16/EN550016
- CISPR 22/EN550022
- VCCI V-3/2004.04
- SAE J551
- SAE J1113
- Full Compliance Testing for Radiated Immunity:
- IEC 61000-4-3/EN61000-4-3
- SAE J551, SAE J-1113
.18 mm (1/8") vinyl floor tile
Design and fabricate RF-shielded enclosure, interior nominal shield-to-shield dimensions of 8.5 m L x 6.1 m W x 5.4 m H, (28 ft L x 20ft W x 19ft H) includes 15.24 cm (6") raised floor
Dielectric vapor barrier and masonite underlayment
ETS-Lindgren 2075-2 MiniMastTM electrically powered air polarization boom tower with 20 m cable and fiber optic feed-through
ETS-Lindgren 2087-2.03 electrically powered, 2 m turntable with cable and fiber optic feed-through
ETS-Lindgren 2090 dual device controller
ETS-Lindgren FS-400, hybrid absorber full coverage of end-wall behind turntable and specular region of ceiling
ETS-Lindgren FS-600, hybrid absorber on specular )'critical") regions of side-walls
ETS-Lindgren FT-1500 for full coverage of transmit end-wall
ETS-Lindgren FT-1500 on non-critical areas of side-walls and ceiling
Field uniformity calibration per IEC 61000-4-3 from 26 MHz to 1 GHz (optional test from 1 - 40 GHz)
Four waveguide vents, 30.48 cm x 30.48 cm (12" x 12")
Guaranteed performance and a five-year limited warranty; one-year warranty on doors, filters and moving parts; two year warranty on optional ETS-Lindgren's equipment
Installation of the enclosure and absorber
Light reflective covers for FS-400 and FS-600 absorber
Normalized site attenuation test per ANSI C63.4-2000 from 30 MHz to 1 GHz (optional test from 1 to 40 GHz)
One 3.81 cm (1.5") pipe penetration with flange nuts and cap
One connector panel, 15.24 cm x 91.44 cm (6" x 36") clear opening
One door maintenance kit
One fiber optic penetration kit
One RF-shielded penetration for airline to MiniMastTM (compressed air is responsibility of customer)
One single-leaf, Series 201, recessed contact mechanism (RCM), manually operated, RF-sheilded door, 1.2 m x 2.13 m (4' x 7') high
One threaded brass ground stud 1.27 cm (0.5") diameter x 12.7 cm (5") long
Raised reflective ground plane, 15.24 cm (6")
Shield test per MIL-STD-285, one frequency test at 1 GHz
Sixteen pieces of ETS-Lindgren EHP-18PCL pyramidal absorber on an area of the floor for radiated immunity testing from 1 GHz up to 40 GHz
Sixteen pieces of ETS-Lindgren FT-100c ferrite tile panels for an area of the floor for radiated immunity testing up to 1 GHz
Three 2 x 30 amp, 60 Hz power-line filters for lights and EUT (wiring not included)
Two "N" type connectors
Two access hatches in raised floor, 45.72 cm x 45.72 cm (18" x 18")
CCTV monitoring system
Electrical distribution
Ferrite tile mounted on rolling carts
Field uniformity measurement up to 18 GHz
Fire detection and suppression system
Heating, ventilating, and air conditioning (HVAC) system
Intercom system
Low profile door sill for Series 201 door
Normalized Site Attenuation measurement up to 18 GHz
Other door options available
Preparation of FCC filing paperwork (class B)
Seismic structural design calculations and certification
Seismic Structural Package
Shielded control room 3.05 m x 3.05 m x 2.44 (10' x 10' x 8')
Specifications
| Absorber Type | EHP-18CL Absorber FS-600 FS-400 FT-100c ferrite panels FT-1500 ferrite tile |
| IEC 1000-4-3 Field Uniformity | 0+6 dB 1.5 m x 1.5 m 26 MHz - 18 GHz 75% 16 points |